    Specification Parameter

    Model

    Water yield

    Membrane Area

    inlet passage

    gpd(m³/d)

    ft2 (㎡)

    mil(mm)

    FFM-N2540GBS-200

    700 (2.65)

    18.3(1.7)

    30(0.8)

    618 (2.34)

    16.1(1.5)

    46(1.2)

    FFM-N4040GBS-200

    2473 (9.36)

    65.0(6.0)

    30(0.8)

    1982 (7.5)

    52.0(4.8)

    46(1.2)

    FFM-N8040GS-200

    11,941 (45.2)

    312(29)

    30(0.8)

    9,485 (35.9)

    247(23)

    46(1.2)



    OPERATION PARAMETERS   

     

    Maximum operating pressure:                                  

    1015 psi (70bar)

     

    Maximum operating temperature:                               

    146°F (60℃)

     

    Maximum cleaning temperature:                                 

    146°F (60℃)

     

    PH range of continuous operation:                            

    2-12

     

    PH range of online cleaning:                                   

    1-13

     

    Design pressure drop of single membrane element:             

    7.3 psi (0.5 bar)


    FFM-N2540GBS-200                                                     Download


    FFM-N4040GBS-200                                                     Download


    FFM-N8040GS--200                                                     Download


    The vast majority of membrane components on the market are applicable to the pH range of feed solution 2-11. However, many pharmaceutical / biochemical / food industrial applications require production under harsh conditions of organic solvents.


    FFM Inc membrane has super stability and meets the application requirements of high and low pH value, high temperature (up to 158 ° f or 70 ° C) and organic media in the market.



    Specification Parameter

    Model

    Water yield

    Membrane Area

    inlet passage

    gpd(m³/d)

    ft2 (㎡)

    mil(mm)

    FFM-N2540GBS-200

    700 (2.65)

    18.3(1.7)

    30(0.8)

    618 (2.34)

    16.1(1.5)

    46(1.2)

    FFM-N4040GBS-200

    2473 (9.36)

    65.0(6.0)

    30(0.8)

    1982 (7.5)

    52.0(4.8)

    46(1.2)

    FFM-N8040GS-200

    11,941 (45.2)

    312(29)

    30(0.8)

    9,485 (35.9)

    247(23)

    46(1.2)



    OPERATION PARAMETERS   

     

    Maximum operating pressure:                                  

    1015 psi (70bar)

     

    Maximum operating temperature:                               

    146°F (60℃)

     

    Maximum cleaning temperature:                                 

    146°F (60℃)

     

    PH range of continuous operation:                            

    2-12

     

    PH range of online cleaning:                                   

    1-13

     

    Design pressure drop of single membrane element:             

    7.3 psi (0.5 bar)